Tuotteet
Näytetään tulokset 568–576 / 1433
-
CMP – PX2K holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Armoured cables
• Metal-to-metal armour clamping
• Direct & remote installation
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested -
CMP – PX2KX holkkitiiviste Atex
Ex eb, Ex db, Ex nR & Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Braid & Tape Armoured Cables
• Metal-to-metal armour clamping
• Direct & remote installation
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested -
CMP – PX2KW holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Steel & Aluminium Wire Armoured Cables
• Metal-to-metal armour clamping
• Direct & remote installation
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested -
CMP – PX2KPB holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Lead Sheathed Armoured cables
• Effectively earths / grounds lead sheathed cables
• Metal-to-metal armour clamping
• Direct & remote installation
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +85°C
• Internationally marked, IECEx & ATEX
• EMC tested -
CMP – PXSS2K holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Unarmoured & Braid Armour Cables
• Direct & remote installation
• Superior levels of cable retention
• Displacement type environmental seal
• Compound barrier type flameproof seal
• Designed to prevent Coldflow
• Deluge protected
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22
• Globally marked, IECEx, ATEX, UL & cCSAus -
CMP – PXRC holkkitiiviste Atex
Ex eb, Ex db, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Unarmoured Cables
• Designed for rigid & flexible conduits
• Easy install running coupler design
• Compound barrier type flameproof seal
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22
• Internationally marked, IECEx & ATEX -
CMP – PXRCREX holkkitiiviste Atex
Ex eb, Ex db, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Unarmoured & Braid Cables housed in Conduit
• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Designed for rigid & flexible conduits
• Easy install running coupler design
• Compound barrier type flameproof seal
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22
• Internationally marked, IECEx & ATEX -
CMP – Sentinel, korroosiosuoja holkkitiivisteelle
The Ultimate Protective Shield in Harsh Corrosive Environments for TMC2 & TMC2X
– Offers long term reliability of cable terminations
– Extends the life span of the gland
– Quick and easy installation, no special tools required
– Clear, visible external identification
– Fully Inspectable
– Fully resistant to potash, UV & salt spray
– Low smoke & fume, zero halogen, flame retardant to UL94-HB
– Supplied with clearance hole and threaded entry interface seals -
CMP – SS2KHT holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable Gland for all types of Unarmoured & Braid Armour CablesDouble Seal, Internationally Approved, Explosive Atmosphere Cable Gland
• -20°C to 200°C high temperature ThermEx seals
• Provides double seal on outer sheath or single on outer & inner
• Direct & remote installation
• Superior levels of cable retention
• Displacement type flameproof seals
• Designed to prevent Coldflow
• Deluge protected
• Class I Zone 1, 21 and Zone 2, 22
• Internationally marked IECEx & ATEX