CMP – Triton CDS PB (T3CDSPB) holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable Gland for all types of Lead Sheathed Armoured Cables• Effectively earths / grounds lead sheathed cables
• Fully sequential, three step installation procedure
• Direct & remote installation
• Unique compensating displacement seal system (CDS)
– Metal-to-metal installation every time regardless of lead sheath diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested -
Gems 3100/3200 – painelähetin (OEM)
Gems 3100- ja 3200-sarjat tarjoavat korkeatasoista vakautta ja luotettavuutta.
Ohutkalvotekniikka ja lyömätön hinta-laatusuhde pienessä koossa.
Sähkö- ja paineliitäntöjen laaja valikoima mahdollistaa monipuolisen varastotarjonnan useimpiin sovelluksiin ilman modifiointia.
• erinomainen pitkäaikaispysyvyys
• alueet 0-7 bar … 0-2,200 bar
• kostuvat osat ruostumatonta terästä (17-4 PH)
• laaja valikoima ulostuloja, sähkö- ja paineliitäntöjä
• optiona kaksoispaine- ja lämpötilamittaus -
CMP – Triton TE1FU holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable Gland for all types of Armoured Cables• Stainless steel compact design
• Fully sequential, three step installation procedure
• Reduces installation times, cost & risk
• Direct & remote installation
• Unique compensating displacement seal system(CDS)
• Metal-to-metal installation regardless of cable bedding diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested -
CMP – Triton TE1FUPB holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable Gland for all types of Lead Sheathed Armoured Cables• Stainless steel compact design
• Effectively earths / grounds lead sheathed cables
• Fully sequential, three step installation procedure
• Reduces installation times, cost & risk
• Direct & remote installation
• Unique compensating displacement seal system(CDS)
• Metal-to-metal installation regardless of lead sheath diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested -
CMP – A2F100 holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor all types of Unarmoured & Braided Cables
• Complies 100% with IEC 60079-0 cable retention requirements
• No external cable clamping required
• No special conditions for safe use
• Displacement type flameproof seal
• Deluge protected
• -60°C to +130°C
• Internationlly marked, IECEx, ATEX -
CMP – RA2e100 holkkitiiviste
Ex eb, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor all types of Unarmoured & Braided Cables
• Supplied with face seal
• Complies 100% with IEC 60079-0 cable retention requirements
• No external cable clamping required
• No special conditions for safe use
• Displacement type seal
• Deluge protected
• -60°C to +130°C
• Internationally marked, IECEx & ATEX
• 10mm thread lengths available upon request (sizes 32 and below) -
CMP – A2e100 holkkitiiviste
Ex eb, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor all types of Unarmoured & Braided Cables
• Complies 100% with IEC 60079-0 cable retention requirements
• No external cable clamping required
• No special conditions for safe use
• Displacement type seal
• Deluge protected
• -60°C to +130°C
• Internationally marked, IECEx & ATEX
• 10mm thread lengths available upon request (sizes 32 and below) -
CMP – A2F holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor all types of Unarmoured & Braid Armour Cables
• Displacement type flameproof seal
• Deluge protected
• -60°C to +130°C (standard), -60°C to 180°C (ThermEx option A2FHT)
• Globally marked, IECEx, ATEX & CSA
• Class I Zone 1, Class I Division 2 BCD (Canada Only) -
CMP – A2e holkkitiiviste
Ex eb, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor all types of Unarmoured & Braid Armour Cables
• 10mm thread length on sizes 32 and below
• Displacement type flameproof seal
• Deluge protected
• -60°C to +130°C
• Internationally marked, IECEx & ATEXX