RÄJÄHDYSVAARALLISET TILAT
Näytetään tulokset 64–72 / 242
-
CMP – SS2KTA holkkitiiviste
Ex eb, Ex nR, Ex ta
Explosive Atmosphere Cable Gland for all types of Tape Armoured CablesDouble Seal, Ex e, Internationally Approved, Explosive Atmosphere Cable Gland
• Effectively earths / grounds tape armour cables
• Direct & remote installation
• Superior levels of cable retention
• Displacement type flameproof seals
• Designed to prevent Coldflow
• Secure against self-loosening
• -60°C to +130°C
• Internationally marked, IECEx & ATEX -
CMP – CXe holkkitiiviste
Ex eb, Ex ta
Explosive Atmosphere Cable GlandFor Braid & Steel Tape Armoured Cables
Internationally Approved, Ex e, Explosive Atmosphere Cable Gland
• Metal-to-metal armour clamping
• Direct & remote installation
• Permanently crimped, low impedance earth termination
• Secure against self-loosening
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Internationally marked, IECEx & ATEX
• EMC tested -
CMP – CWe holkkitiiviste
Ex eb, Ex ta
Explosive Atmosphere Cable GlandFor all types of Steel & Aluminium Wire Armoured Cables
Internationally Approved, Ex e, Explosive Atmosphere Cable Gland
• Metal-to-metal armour clamping
• Direct & remote installation
• Permanently crimped, low impedance earth termination
• Secure against self-loosening
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Internationally marked, IECEx & ATEX
• EMC tested -
CMP – C2K holkkitiiviste
Ex eb, Ex ta
Explosive Atmosphere Cable GlandFor all types of Armoured cables
Internationally Approved, Ex e, Explosive Atmosphere Cable Gland
• Metal-to-metal armour clamping
• Direct & remote installation
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +130°C (standard), -20°C to 200°C
• Class I Zone 1, 21 and Zone 2
• Internationally marked, IECEx & ATEX
• EMC tested -
CMP – C2KHT holkkitiiviste
Ex eb, Ex ta
Explosive Atmosphere Cable GlandFor all types of Armoured cables
Internationally Approved, Ex e, Explosive Atmosphere Cable Gland
• -20°C to 200°C high temperature ThermEx seals
• Metal-to-metal armour clamping
• Direct & remote installation
• Integral protected deluge seal
• Displacement type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Internationally marked, IECEx & ATEX
• EMC tested -
CMP – E1FU holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor all types of Armoured cables
Globally Approved, Explosive Atmosphere Cable Gland
• Metal-to-metal armour clamping
• Direct & remote installation
• Displacement type flameproof inner seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Designed to prevent Coldflow, see CMP Technical Document TS001 (available upon request)
• -60°C to +130°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 2 ABCD
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested -
CMP – E2FU holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor all types of Lead Sheathed Armoured cables
Globally Approved, Explosive Atmosphere Cable Gland
• Effectively earths / grounds lead sheathed cables
• Metal-to-metal armour clamping
• Direct & remote installation
• Displacement type flameproof inner seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Designed to prevent Coldflow, see CMP Technical Document TS001 (available upon request)
• -60°C to +130°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 2 ABCD
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested -
CMP – E1FX holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor Braid & Steel Tape Armoured Cables
Internationally Approved, Explosive Atmosphere Cable Gland
• Metal-to-metal armour clamping
• Direct & remote installation
• Displacement type flameproof inner seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Designed to prevent Coldflow, see CMP Technical Document TS001 (available upon request)
• -60°C to +130°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 2 ABCD
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested -
CMP – E2FX holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor Lead Sheathed Braided & Steel Tape Armoured cables
Internationally Approved, Explosive Atmosphere Cable Gland
• Effectively earths / grounds lead sheathed cables
• Metal-to-metal armour clamping
• Direct & remote installation
• Displacement type flameproof inner seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Designed to prevent Coldflow, see CMP Technical Document TS001 (available upon request)
• -60°C to +130°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 2 ABCD
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested