RÄJÄHDYSVAARALLISET TILAT
Näytetään tulokset 55–63 / 219
-
CMP – PX2KREX holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Armoured Cables
• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Metal-to-metal armour clamping
• Direct & remote installation
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested -
CMP – PX2KWREX holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Steel & Aluminium Wire Armoured Cables
• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Metal-to-metal armour clamping
• Direct & remote installation
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• -60°C to +85°C
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested -
CMP – PX2KXREX holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Braid & Tape Armoured Cables
• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Metal-to-metal armour clamping
• Direct & remote installation
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• -60°C to +85°C
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested -
CMP – PX2KPBREX holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Lead Sheathed Armoured Cables
• Effectively earths / grounds lead sheathed cables
• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Metal-to-metal armour clamping
• Direct & remote installation
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +85°C
• Internationally marked, IECEx & ATEX
• EMC tested -
CMP – PXSS2KREX holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Unarmoured & Braid Cables
• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Direct & remote installation
• Superior levels of cable retention
• Displacement type environmental seal
• Designed to prevent Coldflow
• Deluge protected
• -60°C to +85°C
• Globally marked, IECEx, ATEX & cCSAus -
CMP – PXSS2KHCREX holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Unarmoured & Braid cables housed in Flexible Hose
• RapidEx liquid pour sealing system
– Enhances reliability, reduces risk
– Reduces man hours
– Reduces cost
• Direct & remote installation
• Superior levels of cable retention
• Displacement type environmental seal
• Designed to prevent Coldflow
• Deluge protected
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22
• Globally marked, IECEx, ATEX & cCSAus -
CMP – PX2K holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Armoured cables
• Metal-to-metal armour clamping
• Direct & remote installation
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested -
CMP – PX2KX holkkitiiviste Atex
Ex eb, Ex db, Ex nR & Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Braid & Tape Armoured Cables
• Metal-to-metal armour clamping
• Direct & remote installation
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested -
CMP – PX2KW holkkitiiviste Atex
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Barrier Cable GlandFor all types of Steel & Aluminium Wire Armoured Cables
• Metal-to-metal armour clamping
• Direct & remote installation
• Compound barrier type flameproof seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• Integral protected deluge seal
• -60°C to +85°C
• Class I Zone 1, 21 and Zone 2, 22 Class I Division 1 & 2 ABCD
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested