RÄJÄHDYSVAARALLISET TILAT
Näytetään tulokset 46–54 / 242
-
Vyrtych VIPET-LED teollisuusvalaisin
Sovellukset: Pöly- ja roiskevesitiivis VIPET-LED-valaisin on suunniteltu työpajojen, kellarien, autotallien, varastojen, sekä muiden julkisten ja tuotantotilojen valaisemiseen.
Jännite: 220-240 V/50-60 Hz AC, 220-240 V DC
Valolähde: LED, 4000K, CRI +80, MacAdam3
Kotelointi: Muovimateriaali PC (polykarbonaatti), harmaa väri RAL 7035
Diffuuseri: PC (polykarbonaatti) opaali
-
Automaatiokeskusten kotelot
-
CMP – Triton CDS (T3CDS) holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor all types of Armoured Cables
• Fully sequential, three step installation procedure
• Reduces installation times, cost & risk
• Direct & remote installation
• Unique compensating displacement seal system (CDS)
– Metal-to-metal installation every time regardless of cable diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C (standard), -20°C to 200°C (ThermEx option T3CDSHT)
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested -
CMP – Triton CDS PB (T3CDSPB) holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable Gland for all types of Lead Sheathed Armoured Cables• Effectively earths / grounds lead sheathed cables
• Fully sequential, three step installation procedure
• Direct & remote installation
• Unique compensating displacement seal system (CDS)
– Metal-to-metal installation every time regardless of lead sheath diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX, UL & cCSAus
• EMC tested -
CMP – Triton TE1FU holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable Gland for all types of Armoured Cables• Stainless steel compact design
• Fully sequential, three step installation procedure
• Reduces installation times, cost & risk
• Direct & remote installation
• Unique compensating displacement seal system(CDS)
• Metal-to-metal installation regardless of cable bedding diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested -
CMP – Triton TE1FUPB holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable Gland for all types of Lead Sheathed Armoured Cables• Stainless steel compact design
• Effectively earths / grounds lead sheathed cables
• Fully sequential, three step installation procedure
• Reduces installation times, cost & risk
• Direct & remote installation
• Unique compensating displacement seal system(CDS)
• Metal-to-metal installation regardless of lead sheath diameter
• Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
• Integral protected deluge seal
• Controlled outer ‘load retention’ seal
• Unique OSTG prevents overtightening
• -60°C to +130°C
• Globally marked, IECEx, ATEX & cCSAus
• EMC tested -
CMP – A2F100 holkkitiiviste
Ex eb, Ex db, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor all types of Unarmoured & Braided Cables
• Complies 100% with IEC 60079-0 cable retention requirements
• No external cable clamping required
• No special conditions for safe use
• Displacement type flameproof seal
• Deluge protected
• -60°C to +130°C
• Internationlly marked, IECEx, ATEX -
CMP – RA2e100 holkkitiiviste
Ex eb, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor all types of Unarmoured & Braided Cables
• Supplied with face seal
• Complies 100% with IEC 60079-0 cable retention requirements
• No external cable clamping required
• No special conditions for safe use
• Displacement type seal
• Deluge protected
• -60°C to +130°C
• Internationally marked, IECEx & ATEX
• 10mm thread lengths available upon request (sizes 32 and below) -
CMP – A2e100 holkkitiiviste
Ex eb, Ex nR, Ex ta
Explosive Atmosphere Cable GlandFor all types of Unarmoured & Braided Cables
• Complies 100% with IEC 60079-0 cable retention requirements
• No external cable clamping required
• No special conditions for safe use
• Displacement type seal
• Deluge protected
• -60°C to +130°C
• Internationally marked, IECEx & ATEX
• 10mm thread lengths available upon request (sizes 32 and below)