Triton Series

Showing all 5 results

  • CMP – Triton CDS (T3CDS) holkkitiiviste

    Ex eb, Ex db, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland

    For all types of Armoured Cables

    • Fully sequential, three step installation procedure
    • Reduces installation times, cost & risk
    • Direct & remote installation
    • Unique compensating displacement seal system (CDS)
    – Metal-to-metal installation every time regardless of cable diameter
    • Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
    • Integral protected deluge seal
    • Controlled outer ‘load retention’ seal
    • Unique OSTG prevents overtightening
    • -60°C to +130°C (standard), -20°C to 200°C (ThermEx option T3CDSHT)
    • Globally marked, IECEx, ATEX, UL & cCSAus
    • EMC tested

  • CMP – Triton CDS PB (T3CDSPB) holkkitiiviste

    Ex eb, Ex db, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland for all types of Lead Sheathed Armoured Cables

    • Effectively earths / grounds lead sheathed cables
    • Fully sequential, three step installation procedure
    • Direct & remote installation
    • Unique compensating displacement seal system (CDS)
    – Metal-to-metal installation every time regardless of lead sheath diameter
    • Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
    • Integral protected deluge seal
    • Controlled outer ‘load retention’ seal
    • Unique OSTG prevents overtightening
    • -60°C to +130°C
    • Globally marked, IECEx, ATEX, UL & cCSAus
    • EMC tested

  • CMP – Triton TE1FU holkkitiiviste

    Ex eb, Ex db, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland for all types of Armoured Cables

    • Stainless steel compact design
    • Fully sequential, three step installation procedure
    • Reduces installation times, cost & risk
    • Direct & remote installation
    • Unique compensating displacement seal system(CDS)
    • Metal-to-metal installation regardless of cable bedding diameter
    • Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
    • Integral protected deluge seal
    • Controlled outer ‘load retention’ seal
    • Unique OSTG prevents overtightening
    • -60°C to +130°C
    • Globally marked, IECEx, ATEX & cCSAus
    • EMC tested

  • CMP – Triton TE1FUPB holkkitiiviste

    Ex eb, Ex db, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland for all types of Lead Sheathed Armoured Cables

    • Stainless steel compact design
    • Effectively earths / grounds lead sheathed cables
    • Fully sequential, three step installation procedure
    • Reduces installation times, cost & risk
    • Direct & remote installation
    • Unique compensating displacement seal system(CDS)
    • Metal-to-metal installation regardless of lead sheath diameter
    • Designed to prevent Coldflow, see CMP Technical Document TS002 (available upon request)
    • Integral protected deluge seal
    • Controlled outer ‘load retention’ seal
    • Unique OSTG prevents overtightening
    • -60°C to +130°C
    • Globally marked, IECEx, ATEX & cCSAus
    • EMC tested

  • CMP – Triton CDS (T3CDSHT) holkkitiiviste

    Ex eb, Ex db, Ex nR, Ex ta
    Explosive Atmosphere Cable Gland for all types of Armoured Cables

    • -20°C to 200°C high temperature ThermEx seals
    • Fully sequential, three step installation procedure
    • Reduces installation times, cost & risk
    • Direct & remote installation
    • Unique compensating displacement seal system (CDS)
    – Metal-to-metal installation every time regardless of cable diameter
    • Designed to prevent Coldflow
    • Integral protected deluge seal
    • Controlled outer ‘load retention’ seal
    • Unique OSTG prevents overtightening
    • Internationally marked, IECEx & ATEX
    • EMC tested